HomeCogenerationHow a cogeneration plant works
Guide · Cogeneration
How a cogeneration plant works
A cogeneration plant generates electricity with natural gas engines and recovers the heat from those engines for your process. With the same fuel you get two products: electricity and useful thermal energy, such as steam, hot water or cooling.
Reviewed by Mario René Córdova de la Peña, electrical engineer and CTO of ENEGRIN, in November 2026
The plant in one minute
- A gas engine drives a generator and produces electricity.
- The heat in the exhaust gases becomes steam, and the heat from engine cooling becomes hot water.
- With an absorption chiller, the heat also yields chilled water.
- A BESS absorbs the peaks so the engines run steadily.
- It can run isolated from the grid or connected to it.
In this guide
To apply this to your plant, an ENEGRIN engineer replies the same business day.
Talk to an engineer1. The principle: one combustion, two products
Every engine turns only part of its fuel’s energy into electricity. The rest leaves as heat: in the exhaust gases and in the water that cools it.
A cogeneration plant recovers that heat with heat exchangers and delivers it to your process. With the same gas you get electricity and heat, and you stop burning separate fuel in your boilers.
2. The parts of the plant
| Part | What it does |
|---|---|
| Natural gas engine | Burns the gas and drives the generator. |
| Generator | Turns the engine’s rotation into electricity. |
| Exhaust gas recovery | A heat exchanger or a recovery boiler takes the heat from the gases and produces steam or hot water. |
| Engine cooling recovery | The water that cools the engine comes out hot and is used in the process. |
| Absorption chiller | Optional. It uses heat to produce chilled water. With it, the plant is a trigeneration plant. |
| BESS | Absorbs demand peaks so the engines run steadily. |
| Control and synchronization switchboard | Shares the load among the engines and holds voltage and frequency. |
| Metering | Records the electricity and heat delivered, and the power quality. |
In ENEGRIN plants the engines are Cummins natural gas engines, there is a standby engine and the plant has a BESS.
3. Where the heat comes from
| Heat source | How it is used |
|---|---|
| Exhaust gases | They are the highest-temperature source. They are used to produce steam. |
| Engine cooling water | It comes out at a lower temperature. It is used for process hot water, washing or preheating. |
| Either of the two, with an absorption chiller | It is turned into chilled water for process or air conditioning. |
How much heat is used depends on your process. That is why the regulation asks you to justify the size of the plant with your thermal demand.
4. The energy balance
A power plant that only generates electricity loses a good part of the fuel’s energy as heat. Cogeneration recovers part of that heat.
Out of every 100 units of gas, how many are put to use?
Move the two sliders. The starting values are an example: your plant’s balance comes from its design.
Overall efficiency: 85%
Out of every 100 units of energy in the gas, 40 come out as electricity, 45 as useful heat for your process and 15 are lost.
According to CONUEE, cogeneration saves 20% to 45% of primary energy, from its conversion efficiency alone.
5. Topping cycle and bottoming cycle
The CNE provisions distinguish three cases:
| Case | How it works |
|---|---|
| Topping cycle | Electricity is generated first. The residual heat is used in the process. This is the case of gas engines at an industrial plant. |
| Bottoming cycle | The process comes first. Its unused thermal energy is used to generate electricity. |
| Bottoming cycle with residual fuels | Electricity is generated with fuels the process itself produces. |
6. How it follows your plant’s demand
A gas plant is most efficient close to its optimal load point. But your plant’s demand rises and falls all day. That is why the plant has a BESS, which absorbs the peaks. The engines run close to maximum efficiency, and power quality is guaranteed by contract.
- Voltage regulation ±1% in steady state.
- Frequency 60 Hz ±0.2%.
7. Isolated or connected to the grid
A cogeneration plant can run isolated, with a private network for your plant, or connected to CFE’s grid. Either way it is self-consumption, and from 0.7 MW it requires a generation permit.
ENEGRIN only builds it isolated, because voltage and frequency stay under the plant’s control and grid outages do not reach your process.
Your CFE contract stays active as backup. The gas plant and CFE’s grid are never connected to each other: your plant takes its energy from one or the other. While the plant runs, the only part of your CFE bill you pay is the fixed charge. Isolated and grid-connected self-consumption
8. What your plant needs
- Demand of 1 MW or more.
- Access to natural gas.
- A process that uses steam, hot water or cooling. With no use for heat, it is on-site gas generation.
- Space on your site for the plant.
9. Frequently asked questions
How does a cogeneration plant work?
A gas engine drives a generator and produces electricity. The heat in its exhaust gases and its cooling circuit is recovered in heat exchangers and delivered to the process as steam or hot water.
Which fuel does it use?
Natural gas is the most common in industry. The regulation also recognizes cogeneration with heat a process does not use and with fuels the process itself produces.
What are the topping cycle and the bottoming cycle?
In the topping cycle electricity is generated first and the leftover heat goes to the process. In the bottoming cycle it is the other way around: heat the process no longer uses is used to generate electricity.
What happens if an engine fails?
The plant is designed with a standby engine. In ENEGRIN plants, availability is guaranteed by contract.
Why does a cogeneration plant have a BESS?
To absorb demand peaks. That way the engines run close to their optimal point even as the plant’s load rises and falls during the day.
More on generating your own energy
- Industrial cogeneration in MexicoWhat it is, when it makes sense and which permits it requires
- Self-consumption, distributed generation and PPAsHow to generate or buy your energy
- Electricity Sector LawWhat changes for industry
If your plant draws 1 MW or more and has access to gas, let’s talk.
An ENEGRIN engineer replies the same business day.
Sources
- CNE, general administrative provisions for electricity generation in the cogeneration mode, Official Gazette (DOF), April 16, 2026: section 2.3 (topping and bottoming cycle) and section 2.6 (capacity justified with thermal demand).
- Electricity Sector Law (Ley del Sector Eléctrico), Official Gazette (DOF), March 18, 2025, current text from the Chamber of Deputies: article 41: cogeneration mode.
- CONUEE and GIZ, “Guía práctica de trámites y permisos para proyectos de cogeneración de energía eléctrica en México” (2012): primary energy savings of cogeneration and the conditions under which it makes sense.
- Plant data: specifications of ENEGRIN’s cogeneration plants.